INSTALLATION AND OPERATING INSTRUCTIONSNWS RESIDENTIALWATER SOFTENERS MODELS: NWS100 NWS100M NWS150 NWS150M NWS200 NWS200MINSTR2208 1111Installer,
Step 1(a) Remove unit from shipping box, inspect for damage and ensure all parts needed for installa-tion are present. If parts are missing please
Step 7Install overfl ow line to brine tank overfl ow fi tting (Figure 3). Discharge of line must be lower than overfl ow fi tting. Do not interconnect ov
2-4Step 12Before loading salt, using a pail or garden hose, add approximately 3 gals. water to brine tank (6 gals. for units with extended grid legs).
3-1SECTION 3: REGENERATION INSTRUCTIONSINSTRUCTIONS FOR USING REGENERATION FREQUENCY SCHEDULES: (Time Clock Initiated Models Only) 1) Determine adjus
3-2Model(s) 200HARDNESS — gpgPersons InFamily5 10152025303540455055601 1111111111122 1111122222233 1112222333344 1122233344465 1122334446666 122334466
3-3HOW TO SET METER REGENERATION CONTROL: TYPICAL RESIDENTIAL APPLICATION: To program, just set the time, set the hardness and it automatically monito
4-1SECTION 4: SERVICE INSTRUCTIONSProblem Cause Solution1) Hard water, (unit NOT using salt; liquid level in brine tank NOT too high).A. Electrical se
5-1SECTION 5: SPECIFICATION AND OPERATING DATATime Clock Initiated Meter InitiatedITEM NWS100 NWS150 NWS200 NWS100M NWS150M NWS200MNominal Media Volum
6-112345678910111213141aNWS/NWS-M SERIES COMPONENTS PARTS LIST TWO TANK MODELSREF NO. DESCRIPTION NWS100NWS100MNWS150NWS150MNWS200NWS200M1 Control Val
6-2
6-3ONLY THOSE PARTS CIRCLED IN DRAWING AND/OR LISTED BELOW ARE STOCK ITEMSALL OTHERS ARE SPECIAL ORDER, NON-RETURNABLEPARTS LIST - 12 DAY TIMERREF PAR
6-5ONLY THOSE PARTS CIRCLED IN DRAWING AND/OR LISTED BELOW ARE STOCK ITEMSALL OTHERS ARE SPECIAL ORDER, NON-RETURNABLEPARTS LIST - METER TIMER REF PA
7-1SECTION 7: MAINTENANCEREPLENISHMENT OF SALT SUPPLY: The salt storage capacity of the brine tank is approximately 160 lbs. During each regeneration
Aqua-Pure is a trademark of 3M Company used under license.3M is a trademark of 3M Company.© 2011 3M Company. All rights reserved.3M Purifi cation Inc.
SAFETY INFORMATIONRead, understand, and follow all safety information contained in these instructions prior to installation and use of the NWS Series
TABLE OF CONTENTS SECTION DESCRIPTION 1 BEFORE INSTALLATION 2 INSTALLATION 3 REGENERATION INSTRUCTIONS (Timing Setting Instructions) 4 SERVICE INS
Check Your Pumping Rate and Water Pressure:Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage
1-3Facts to Remember While Planning Your Installation: 1) All installation procedures MUST conform to local and state plumbing codes. 2) If lawn
SECTION 2: INSTALLATIONProper installation sequence of water conditioning equipment is very important. Refer to the following diagram for your partic